White Rodgers 36C74 User Manual

Browse online or download User Manual for Cookers White Rodgers 36C74. White Rodgers 36C74 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Printed in U.S.A.
PART NO. 37-5868A
Replaces 37-5153A
9732
WHITE-RODGERS
CONTENTS
Description ......................................................... 1
Specifications ..................................................... 1
Precautions ........................................................ 2
Installation .......................................................... 3
Main Piping Connection
Pilot Gas Connection
System Wiring
Adjustment ......................................................... 4
Pilot Flame Adjustment
Pressure Regulator Adjustment
Pilot Lighting Instructions and Precautions ........ 5
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.
DESCRIPTION
The 36C74 Gas Valve is for use on systems providing
automatic ignition of the pilot and/or main burners and
incorporates the following features: pilot/redundant sole-
noid valve, main valve, integral pressure regulator and
male spade terminals for point-to-point wiring.
This gas valve is also equipped with a step-opening
feature to provide for quieter main burner ignition. The
valve opens partially until main burner flame is estab-
lished, then the valve opens to full operating pressure.
Electrical Rating:
24 VAC (30 Volts max. Voltage), 60 Hz.
Types of Gases: Natural or LP Gas
Pressure Rating: 14” W.C. (
1
2 PSI)
Ambient Temperature: -40° to 175°F (-40° to 79°C)
Regulator Adjustment Range:
Natural Gas: 2.5” to 5.0” W.C. (Full flow)
LP Gas: 7.5” to 12.0” W.C. (Full flow)
(Step pressure not adjustable)
SPECIFICATIONS
INSTALLATION INSTRUCTIONS
Type 36C74
Combination Gas Valve
INLET BOSS
UP OR DOWN
UPRIGHT
LEFT OR RIGHT
Upright, 90° from upright or vertical
NOTE: Control shown may not be identical
to replacement control.
ON
OFF
Figure 1. Mounting Positions
PIPE SIZES/CAPACITIES
Pipe Size
(inches)
Capacity (BTU/hr) at
1" pressure drop across valve
1
/2" x
3
/8"
1
/2" x
1
/2"
1
/2" x
3
/4"
3
/4" x
3
/4"
100,000
230,000
230,000
280,000
162,000
372,600
372,600
453,600
Nat. Gas
(1000 BTU/cu. ft.,
64 Sp. Gr.)
LP Gas
(2500 BTU/cu. ft.,
1.53 Sp. Gr.)
OFF
ON
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - Type 36C74

Printed in U.S.A.PART NO. 37-5868AReplaces 37-5153A9732WHITE-RODGERSCONTENTSDescription ... 1Spe

Page 2 - THE FOLLOWING PRECAUTIONS

2DO NOT BEGIN INSTALLATION UNTIL YOU READTHE FOLLOWING PRECAUTIONS.PRECAUTIONS1. Failure to turn off electric or main gas supplyto heating system coul

Page 3 - PILOT GAS CONNECTION

3INSTALLATIONMAIN PIPING CONNECTIONSAll piping must comply with local codes, ordinances,and/or national fuel gas codes.1. Turn off electrical power to

Page 4

4SYSTEM WIRINGREFER TO AND FOLLOW THE APPLIANCEMANUFACTURER’S WIRING DIAGRAM. REFER TOFIG. 4 FOR TERMINAL IDENTIFICATION.INSTALLATION (con’t)Pilot Adj

Page 5 - AND PRECAUTIONS

5PILOT LIGHTING INSTRUCTIONSAND PRECAUTIONSFOR YOUR SAFETY READ BEFORE LIGHTINGWARNING!If you do not follow these instructions exactly, a fire or expl

Page 6 - 9797 Reavis Road

If you need more information about this product, please write to us at:WHITE-RODGERS DIVISION, Emerson Electric Co.9797 Reavis RoadSt. Louis, MO 63123

Comments to this Manuals