White Rodgers 1F86-344 Installation Manual

Browse online or download Installation Manual for Thermostats White Rodgers 1F86-344. White Rodgers 1F86-344 Installation and Operation Instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
CAUTION
!
WARNING
!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
Your new White-Rodgers Digital Thermostat uses the technol-
ogy of a solid-state microcomputer to provide precise tempera-
ture control.
Features:
Simultaneous heat and cool setpoint storage
Pre-set temperature control
Backlit display
LCD continuously displays setpoint and room temperature
°F/°C convertibility
Temperature range 45° to 90°F
RC, RH, C, W, Y, G , O and B terminals
Optional C terminal (Dual Power option)
B and O terminals for single stage heat pumps (no auxiliary
heat) or damper operation
Setpoint storage in case of power loss
2 "AA" alkaline batteries included
SPECIFICATIONS
ELECTRICAL DATA
Electrical Rating:
8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-4°F to 150°F
APPLICATIONS
For use with:
Standard heat/cool or heat only systems
Electric heat systems
Gas or oil fired systems
Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers
Hydronic (hot water or steam) systems
Single-stage heat pump systems (no auxiliary heat)
Millivolt systems
DO NOT USE WITH:
Multi-stage systems
Systems exceeding 30 VAC and 1.5 amps
3-wire zoned hydronic heating systems
1F86-344
Non-Programmable Electronic Digital Thermostat
PART NO. 37-6585B
Replaces 37-6585A
0745
INSTALLATION AND
OPERATION INSTRUCTIONS
PRECAUTIONS
This thermostat is intended for use with a low voltage system;
do not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contrac-
tor or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes
and ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could
cause the control to malfunction.
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the sys-
tem shall conform to Class II circuits per the NEC code.
Operator: Save these instructions for future use!
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - 1F86-344

CAUTION!WARNING!FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLYBEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSEPERSONAL INJURY AND/OR PRO

Page 2 - INSTALLATION

4de configuración. La pantalla mostrará la primera opción del menúdeconguración.En el cuadrodel menú de conguración a continuación seresu

Page 3 - Cooling System

52) Seleccione Display Backlight (luz de fondo de pantalla) (d-L OFF [desactivada] u ON [activada]) - La luz de fondo mejora el contraste de la panta

Page 4 - OPERATION

El logotipo de Emerson es una marca comercial y una marca de servicio de Emerson Electric Co.LÍNEA DE AYUDA PARA EL USUARIO: 1-800-284-2925St. Louis,

Page 5 - SETTING THE THERMOSTAT

2INSTALLATIONREMOVE OLD THERMOSTAT1. Shut off electricity at the main fuse box until installation iscomplete. Ensure that electrical power is disconne

Page 6 - The Emerson logo is a

3RHY24 VAC120 VACHotNeutralTHERMOSTATSYSTEMG WFigure 5. Typical wiring diagram forheat/cool, 5-wire, two-transformer systemsHEATINGTRANSFORMERHeatingS

Page 7

4CONFIGURATION MENUThe configuration menu allows you to set certain thermostatoperating characteristics to your system or personal require-ments.Move

Page 8 - RETIRE EL TERMOSTATO VIEJO

52) Select FA or SL (Fast or Slow) Heating Cycle Rate - TheFA setting is frequently used for gas, oil or electric heat. TheSL setting produces a longe

Page 9 - ¡PRECAUCIÓN!

www.white-rodgers.comSt. Louis, Missouri Markham, OntarioThe Emerson logo is atrademark and service mark of Emerson Electric Co.HOMEOWNER HELP LINE:

Page 10 - RETLIFYRETTAB

Este termostato está diseñado para ser utilizado con un sistema de bajo voltaje; no utilice este termostato con un sistema de voltaje de línea. Si ti

Page 11 - AJUSTE DEL TERMOSTATO

2INSTALACIÓNRETIRE EL TERMOSTATO VIEJO1. Apaguelaelectricidadenlacajadefusiblesprincipalhastaque haya nalizado la instalación. Asegúr

Page 12 - El logotipo de Emerson

3RHY24 VAC120 VACVivoNeutroSISTEMATERMOSTATOG WFigura 5. Diagrama de conexiones típico para sistemas de calor/frío de dos transformadores y 5 cablesTR

Comments to this Manuals

No comments