THERMOSTATS
MECHANICAL
THERMOSTATS
1E30N-910
1F56N-444
1F56N-361
PAGE
165
MECHANICAL THERMOSTATS – MERCURY FREE
Replaces Hundreds of White-Rodgers and Competitive Models.
Enclosed Snap Action Contacts for Reliable, Economical and
Environmentally Friendly Control
FEATURES
• Mercuryfreesnap-actioncontactswithdustcover.
• Resistanttovibration.
• Mountstowallorjunctionbox.
• Builtinbimetalthermometer.
• ClassicWhitecolor.
• HorizontalandVerticalmodels.
• 24Volt,750mVand3-wirezoneoptions.Seetablebelow.
SPECIFICATIONS
Electrical Rating . . . . . . . . . . . . . . . . . . 20-30VAC,NECClassII50/60Hz
Heating ......................... 0.15to1.2Amps
Cooling ......................... 0.15to1.2Amps
Heat Anticipator .................. Adjustablefrom0.15to1.2Amps
Cool Anticipator .................. Fixed
Differential Heat .................. 1°F
Differential Cool .................. 1.5°F
Setpoint Range................... 50°Fto90°F(10°Cto32°C)
Operating Humidity Range .......... 0-90%non-condensing
Dimensions......................4
1
/
2
”Hx2
3
/
4
”Wx1
1
/
2
”D–1E(Vertical)
4
1
/
2
”Hx3
1
/
4
”Wx1
5
/
8
”D–1EwithHeat/
Cool Subbase
2
3
/
4
”H4
1
/
2
”Wx1
1
/
2
”D – 1 F ( H o r i z o n t a l )
3
1
/
4
”Hx4
1
/
2
”Wx1
5
/
8
”D–1FwithHeat/
Cool Subbase
PARTS AND ACCESSORIES See end of thermostats section for additional parts and accessories
• F61-2301—Wallplate5
5
/
8
”Wx5
3
/
4
”Hwithadapterplatetohorizontalorvertical
junctionbox
• ThermostatGuards—seepages34–35
TECHNICAL HELP
Conguration/Wiring................... Seepage165
Model
Number
Orientation
Vertical, Horizontal
Applications Options
Control Range Terminals
Heat Only
Cool Only
Heat-Cool
Conventional Gas /
Oil / Electric
Electric Strip Heat
Heat Pump (No Aux.)
3-Wire Zone Valve
Millivolt Compatible
Includes Optional F92-0563
Kit for Temperature Locking
or Limiting
Includes Switched Subbase
Heat-Off-Cool & Fan Auto-On
Includes Switched Subbase
Heat-Off
Includes Wallplate Heat Only
(No System or Off Switch)
Includes Wallplate
Cool Only or 3-Wire Zone
(No System or Off Switch)
1E30N-910 V
3 3 3 3
50to90°F R, W
1E50N-301 V
3 3 3 3 3 3 3 3 3 3 3 3 3
50to90°F R, W
1E56N-444 V
3 3 3 3 3 3 3 3 3 3 3
50to90°F RC,RH,W,Y,O,B,G,A
1F56N-444 H
3 3 3 3 3 3 3 3 3 3 3
50to90°F RC,RH,W,Y,O,B,G,A
1E30N-311 V
3 3 3 3
50to90°F/10to32°C R, W
1E50N-303 V
3 3 3 3 3 3
50to90°F/10to32°C R, W
1E56N-361 V
3 3 3 3 3 3 3 3 3 3 3
50to90°F/10to32°C RC,RH,W,Y,O,B,G,A
1F56N-361 V
3 3 3 3 3 3 3 3 3 3 3
50to90°F/10to32°C RC,RH,W,Y,O,B,G,A
IndicatesCanadianModelNumber:call1-800-305-6953toorder
24 VOLT
R-4425-24E
www.white-rodgers.com
24