WHITE-RODGERS 90 SERIES
1F95CA-391
MULTI-STAGE/HEAT PUMP INSTALLATION/CONFIGURATION
This White-Rodgers Digital Thermostat uses
microcomputer technology to provide precise
time, humidity, and temperature control. This
thermostat offers the flexibility to design
1F95CA-391: 7 Day programming;
residential applications.
ELECTRICAL DATA
Electrical Rating:
20 to 30 VAC, 50/60 Hz with common
0.05 to 1.5 Amps per terminal
2.5 Amps maximum total load (all
terminals combined).
Hardwired only.
C terminal is required.
INSTALLATION
Part No. 37-6583A
0504
DESCRIPTION
SPECIFICATIONS
heating and cooling programs that fit
building needs. This thermostat is adaptable
to most 24 volt residential forced air multi-
Standard Systems:
Multi-stage gas, oil, electric.
Single-stage or two-stage compressor
heat pump.
THERMAL DATA
Setpoint Temperature Range:
45° to 99°F (7° to 37°C)
Operating Ambient Temperature:
32° to 110°F (0° to 43°C)
Operating Humidity Range:
90% non-condensing max.
Shipping Temperature Range:
-4° to 149°F (-20° to 65°C)
PRECAUTIONS
Do not short out terminals on gas valve
or primary control to test. Short or
incorrect wiring will damage thermostat
and could cause personal injury and/or
property damage.
Do not use on circuits exceeding
specified voltage. Higher voltage will
damage thermostat and could cause
shock or fire hazard.
Thermostat installation and all compo-
nents of the system shall conform to
Class II circuits per the NEC code.
To prevent electrical shock and/or
equipment damage, disconnect electric
power to system at main fuse or circuit
breaker box until installation is
complete.
Read all instructions thoroughly before
beginning installation.
This thermostat is intended for use with a
low voltage system. Do not use on a line
voltage system.
CAUTION
!
WARNING
!
Do not exceed ratings shown in the Specifi-
cations section, above. If in doubt about the
electrical ratings of your heating/cooling
system, have it inspected by a qualified
heating and air conditioning contractor or
licensed electrician.
All wiring must conform to local and
national electrical codes and ordinances.
This control is a precision instrument, and
should be handled carefully. Rough handling
or distorting components could cause the
control to malfunction.
NOTE
stage or heat pump systems with electric or
fossil fuel auxiliary.
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - 1F95CA-391

WHITE-RODGERS 90 SERIES1F95CA-391MULTI-STAGE/HEAT PUMP INSTALLATION/CONFIGURATIONThis White-Rodgers Digital Thermostat usesmicrocomputer technology to

Page 2 - INSTALLATION

No Heat/No Cool/No Fan 1. Blown fuse or tripped circuit breaker. Replace fuse or reset breaker.(Common Problems) 2. Furnace power switch to OFF. Turn

Page 3 - MULTI-STAGE TERMINAL OUTPUTS

No Cool 1. SYSTEM button not pressed to display COOL. Set SYSTEM button until COOL is displayed andraise temperature below room temperature.2. Loose c

Page 4 - CONFIGURATION

The Emerson logo is atrademark and a service mark of Emerson Electric Co.Why does the system run with thesetpoint and room temperature thesame?How do

Page 5

ATTENTION!This product does not contain mercury.However, this product may replace a unitwhich contains mercury.Do not open mercury cells. If a cell be

Page 6

HEAT PUMP TERMINAL OUTPUTSRefer to equipment manufacturers’ instruc-tions for specific system wiring information.You can configure the thermostat for

Page 7 - HEATING COOLING

RESET SWITCHSee the Troubleshooting section at the endof this document for more information aboutthe function of this switch.E2/P SWITCH (DHM) TERMINA

Page 8 - Returns to Normal Operation

INSTALLER CONFIGURATIONBEFORE TURNING POWER ON, pleaseread the following instructions. Beforeoperating the system, you must configurethe thermostat to

Page 9 - CHECK THERMOSTAT OPERATION

INSTALLER TABLENOTE: You must be in the User Configuration Menu to enter the Installer Table. Firmly press TIME FWD andTIME BACK at same time and rele

Page 10 - TROUBLESHOOTING

These numbers are approximate and represent operation with a typical system. Actual temperature differentials andrun times may vary widely based on yo

Page 11

The Service Button Menu allows you to view or program as many as 4 reminders that indicate when service is required.1. Humidifiers = A programmable ru

Page 12 - The Emerson logo is a

9CHECK THERMOSTAT OPERATIONFAN OPERATIONIf your system does not have a G terminalConnection, skip to HEATING SYSTEMsection below.1. Turn power on to t

Comments to this Manuals

No comments