Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the
system shall conform to Class II (current limited) cir-
cuits per the NEC code. Failure to do so could cause a
fire hazard.
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
Your new White-Rodgers Digital Thermostat uses the
technology of a solid-state microcomputer to provide precise
temperature control.
Features:
Simultaneous heat and cool setpoint storage
Setpoint storage in case of power loss
Pre-set temperature control
LCD continuously displays setpoint and room temperature
Continuous Backlit display option
°F/°C convertibility
Temperature range 45° to 90°F
R, C, Y, W2, G, O/B, E, and L terminals for single or two-
transformer systems
Optional "AA" batteries to provide continuous temperature
display during loss of AC power
SPECIFICATIONS
ELECTRICAL DATA
Electrical Rating:
20 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-4°F to 149°F
APPLICATIONS
For use with:
Standard heat pump systems with electric, gas or oil Aux
heat with 24 VAC HOT and COMMON available
Single-stage heat pump systems with no Aux heat with
24 VAC HOT and COMMON available
DO NOT USE WITH:
Millivolt systems
Systems exceeding 30 VAC and 1.5 amps
3-wire zoned hydronic heating systems
1F89-211
Non-programmable Electronic Digital
Heat Pump Thermostat
INSTALLATION AND
OPERATION INSTRUCTIONS
Printed in U.S.A.
PART NO. 37-6233D
Replaces 37-6233C
0225
WHITE-RODGERS
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
www.white-rodgers.com
PRECAUTIONS
CAUTION
!
This thermostat is intended for use with a low voltage system; do
not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contractor
or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and
ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system at main fuse
or circuit breaker box until installation is complete.
WARNING
!
Operator: Save these instructions for future use!
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - 1F89-211

Do not use on circuits exceeding specified voltage.Higher voltage will damage control and could causeshock or fire hazard.Do not short out terminals o

Page 2 - INSTALLATION

2INSTALLATIONREMOVE OLD THERMOSTAT1. Shut off electricity at the main fuse box until installation iscomplete. Ensure that electrical power is disconne

Page 3 - TAPE OFF!

3LRE24 VAC120 VACHotSYSTEMMONITORSWITCHNeutralTHERMOSTATSYSTEMG W2Figure 2. Typical wiring diagram for single transformer systemsTRANSFORMER(Class II

Page 4 - OPERATION

4CONFIGURATION MENUThe configuration menu allows you to set certain thermostatoperating characteristics to your system or personal require-ments.Move

Page 5 - Configuration Menu

52) Select FA or SL (Fast or Slow) Heat Pump stage CycleRate - The FA setting is used to produce shorter heatingcycles. The SL setting produces a lon

Page 6 - Reset Operation

6TROUBLESHOOTINGSymptom Possible Cause Corrective ActionNo Heat/No Cool/No Fan 1. Blown fuse or tripped circuit breaker. Replace fuse or reset breaker

Comments to this Manuals

No comments