INSTALLATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
Installer: Save these instructions for future use!
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire, ex-
plosion, or production of carbon monoxide may result,
causing property damage, personal injury, or loss of
life. The qualified service agency performing the work
assumes the responsibility for the proper conversion
of this appliance with this kit.
APPLICATION
This regulated Natural Gas to unregulated L.P. Gas conversion
kit allows the 36C, 36E and 36J Series gas valves to be used
on L.P. gas applications, PROVIDED an external regulator is
used and the inlet pressure does not exceed 14” W.C. This
conversion kit is for use on all single stage, fast and slow
open models only.
TO CONVERT FROM NATURAL TO L.P. GAS
1. Remove regulator cover screw.
2. Insert the spring (provided in the conversion kit) through the
hole in the center of the plastic regulator adjustment screw.
3. Insert the blocking pin (provided in the conversion kit) down
into the center of the spring.
4. Replace the regulator cover screw.
5. Attach the WARNING label (provided in the kit) to the gas valve
where it can be readily seen. Also attach the small round L.P.
label to the top of the regulator cover screw.
6. If present pilot burner is to be used, the pilot orifice must be
replaced.
Conversion back to Natural Gas use may be made at a later date
by removing the spring and blocking pin (installed in steps 2 and
3, above) and removing the WARNING and L.P. labels.
Figure 1. 36C model
Regulator
Cover Screw
Spring
Blocking Pin
Plastic Regulator
Adjustment Screw
Figure 2. 36E model
Regulator
Cover Screw
Spring
Blocking Pin
Plastic Regulator
Adjustment Screw
Figure 4. Contents of kit
VALVE CONVERTED FOR USE ON L.P.
GAS. REGULATOR BLOCKED OPEN.
EXTERNAL REGULATOR REQUIRED.
IMPROPER OPERATION COULD RESULT
IN DEATH OR SERIOUS INJURY.
WARNING
!
SOUPAPE CONVERTIE POUR USAGE
SUR GAZ DE PÉTROLE LIQUÉFIÉ.
RÉGULATEUR BLOQUÉ EN POSITION
OUVERTE. RÉGULATEUR EXTERNE
NÉCESSAIRÉ. UN FONCTIONNEMENT
INAPPROPRIÉ PEUT PROVOQUER LA
MORT OU DES BLESSURES GRAVES.
MISE EN GARDE
!
WARNING Label
Blocking
Pin
Spring
L.P. Label
LP
White-Rodgers is a division
of Emerson Electric Co.
WARNING
!
Regulator Cover
Screw
Blocking Pin
Spring
Plastic Regulator
Adjustment Screw
Figure 3. 36J model
Page view 0
1 2

Summary of Contents

Page 1 - F92-0737

www.white-rodgers.comPART NO. 37-5382EReplaces 37-5382D0943F92-0737Natural to Unregulated L.P. GasConversion KitINSTALLATION INSTRUCTIONSFAILURE TO RE

Page 2

Ce nécessaire de conversion devra être monté par une agence de service qualifiée conformément aux instructions du fabricant ainsi qu’à tou

Comments to this Manuals