White Rodgers F92-1011 User Manual

Browse online or download User Manual for Unknown White Rodgers F92-1011. White Rodgers F92-1011 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
PART NO. 37-6586B
Replaces 37-6586A
1005
F92-1011
Regulated L.P. to Natural Gas
Conversion Kit for 36G/36J Two-Stage
INSTALLATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
Installer: Save these instructions for future use!
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information in
these instructions is not followed exactly, a fire, explo-
sion, or production of carbon monoxide may result,
causing property damage, personal injury, or loss of
life. The qualified service agency performing the work
assumes the responsibility for the proper conversion
of this appliance with this kit.
APPLICATION
This conversion kit allows the 36G Series and 36J Series Two-
Stage gas valves to be used on Natural gas applications. This
conversion kit is for use on all 36G/36J Two-Stage, fast and
slow open models.
WARNING
!
Figure 2. Contents of kit
Natural Gas Regulator
Springs (silver/plain)
Natural Gas Labels
NAT.
GAS
NAT.
GAS
Regulator
Cover Screw
Regulator Spring
Plastic Regulator
Adjustment Screw
Figure 1. 36G/36J 2-Stage models
High
Low
TO CONVERT FROM L.P. TO NATURAL GAS
1. Remove both regulator cover screws.
2. Remove both regulator adjustment screws (beneath the
cover screws).
3. Remove both regulator springs from regulator sleeves. (L.P.
configuration may be two L.P. springs, color-coded white, or
one L.P., color-coded white, and one Natural, color-coded
silver/plain).
4. Insert the Natural Gas regulator springs (provided in the
conversion kit and color-coded silver/plain) into the regulator
sleeves.
5. Replace the High regulator adjustment screw and adjust
approximately 14 turns from top of sleeve.
6. Replace the Low regulator adjustment screw and adjust
approximately 10 turns from top of sleeve.
7. Adjust both outlet pressures to the appliance manufacturer's
requirements.
8. Replace both regulator cover screws.
9. Remove the L.P. WARNING label, if
present, from the gas valve. Also attach the
small round NAT GAS labels to the top of
the regulator cover screws.
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
VALVE CONVERTED FOR USE ON L.P.
GAS. IMPROPER OPERATION COULD
RESULT IN DEATH OR SERIOUS
INJURY.
WARNING
!
SOUPAPE CONVERTIE POUR USAGE
SUR GAZ DE PÉTROLE LIQUÉFIÉ.
UN FONCTIONNEMENT INAPPROPRIÉ
PEUT PROVOQUER LA MORT OU DES
BLESSURES GRAVES.
MISE EN GARDE
!
WARNING Label
Page view 0
1

Summary of Contents

Page 1 - F92-1011

PART NO. 37-6586BReplaces 37-6586A1005F92-1011Regulated L.P. to Natural GasConversion Kit for 36G/36J Two-StageINSTALLATION INSTRUCTIONSFAILURE TO REA

Comments to this Manuals

No comments