White Rodgers 21D28-6 User Manual

Browse online or download User Manual for Light switches White Rodgers 21D28-6. White Rodgers 21D28-6 Catalog Page [en]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SPECIFICATIONS
Electrical Ratings:
Pilot Duty Pole ..................... 3 VA at 24 VAC (Minimum)
25V at 24 VAC (Maximum)
Input Voltage....................... 24 VAC nominal
Total Power Consumption............. 0.5 VA (relay de-energized)
4.0 VA (relay energized)
57T01-843 BLOWER TIME DELAY RELAY
The 57T01-843 Time Delay Relay is for Use in Air Handlers Installed
in Compressor-Run Air Conditioning and Heat Pump Systems to
Delay the Blower Shut-Off After the Compressor has Shut Off.
Replaces Trane Part Numbers D155079P01 and RLY 2807
FEATURES
•Allowsresidualcooledairtobeblownintothecontrolledspace,increasingthe
efciencyofthesystemincooling.
•Dependingonelectricalhookupinaheatpumpsystem,delayofblowershut-off
could also occur in heating.
Model Number
Contact Ratings:
Power Pole (Amperes per pole)-
57T01-843
208/240/277 VAC
Full Load 7
LockedRotor 36
Resistive 15
U.L. Approved Horsepower
3
/
4
HP
57T01-843
57T01-843 BLOWER
TIME DELAY RELAY
www.white-rodgers.com
84
COOLING /
REFRIGERATION
Page view 0