White Rodgers 1F82-261 Wiring Diagram Page 1

Browse online or download Wiring Diagram for Thermostats White Rodgers 1F82-261. White Rodgers 1F82-261 Wiring and Configuration User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
L
R
E
24 VAC
120 VAC
Hot
SYSTEM
MONITOR
SWITCH
Neutral
SYSTEM
G W2
Single transformer systems
TRANSFORMER
(Class II)
Changeover
Relay*
CYO/B
Compressor
Contactor
* Changeover Relay is energized in COOL when O/B switch is in the “O” position
Changeover Relay is energized in HEAT when O/B switch is in the “B” position
Aux
Relay
(Stage 2)
Fan
Relay
Emergency
Relay
See Note **
** Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency
L
R
E
24 VAC
120 VAC
Hot
SYSTEM
MONITOR
SWITCH
Neutral
SYSTEM
G W2
Two transformer systems with NO safety circuits
TRANSFORMER
(Class II)
Changeover
Relay*
CYO/B
Compressor
Contactor
* Changeover Relay is energized in COOL when O/B switch is in the “O” position
Changeover Relay is energized in HEAT when O/B switch is in the “B” position
Aux
Relay
(Stage 2)
Fan
Relay
Emergency
Relay
Limit or
Safety
Switches
TWO COMMONS MUST
BE JUMPERED TOGETHER!
HOT
NEUTRAL
120 VAC
24 VAC
CUT AND
TAPE OFF!
If safety circuits are in
only one of the systems,
remove the transformer
of the system with NO
safety circuits.
NOTE
** Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency
See Note **
1F82-261 / 1F89-211
Electric/Gas
jumper (W904)
O/B
switch
Reset switch
(below Fan switch)
W904
The following table allows you to customize the options on your Comfort-Set thermostat. Begin by pressing simultaneously the
two buttons in step 1.
Electric / Gas Jumper (Fan Option)
If your emergency or auxiliary system will energize the blower, then
jumperW904,onthethermostatbase,mustbecut(seegureat
left).Ifyouremergencyorauxiliaryheatsystemrequiresthatthe
thermostatenergizethefancircuit,donotcutjumperW904.
O/B Terminal Switch Selection
The O/B switch on this thermostat is factory set to the “O” position.
Thiswillaccommodatethemajorityofheatpumpapplications,which
requirethechangeoverrelaytobeenergizedinCOOL.Ifthether-
mostat you are replacing or the heat pump being installed with this
thermostatrequiresa“B”terminal,toenergizethechangeoverrelay
in HEAT, the O/B switch must be moved to the “B” position.
CONFIGURATION AND
TYPICAL WIRING DIAGRAMS
CONFIGURATION
TYPICAL WIRING DIAGRAMS
1
Displayed (Factory Default) Press or to select: COMMENTS
HOLD
(0:00)
0 to 8 hrs (in
15 minute increments)
2
(SL)
FA
Select temporary Hold time
5
6
E
(on)
OFF
7
8
LOC
(OFF)
on
0 HI
(0)
4 LO to
4 HI
°(F) °C
Returns to normal operation
9
11
Select Energy Management Recovery OFF or ON
Select Compressor lockout OFF or ON
Select temperature display adjustment higher or lower
Select temperature display to °F or °C
Set SYSTEM
switch to OFF
or
4
d-L
(on)
OFF
Select display backlight OFF or ON
Filter
(000)
0 to 1950 hours
(in 50 hour increments)
Select filter replacement run time
Select FA or SL (Fast or Slow) pump cycle rate
Configuration Menu
* Press
HOLD to advance to next item or TIME to move backwards to previous item
3
EMER
(FA)
SL
Select FA or SL (Fast or Slow) Auxiliary and
Emergency Aux heating cycle rate
1F89-211
Press Button(s)
Step
RUN
PRGM
and RUN
HOLD
*
HOLD
*
HOLD
*
HOLD
*
HOLD
*
HOLD
*
HOLD
*
1F82-261
Press Button(s)
or
or
or
or
or
or
or
HOLD
*
FA (ON) OFF
10
Selects fast second stage ON or OFF
HOLD
*
or
www.white-rodgers.com
158
TECHNICAL HELP
Page view 0
1

Summary of Contents

Page 1 - 1F82-261 / 1F89-211

LRE24 VAC120 VACHotSYSTEMMONITORSWITCHNeutralSYSTEMG W2Single transformer systemsTRANSFORMER(Class II)ChangeoverRelay*CYO/BCompressorContactor* Change

Comments to this Manuals

No comments