White Rodgers 1F97-71 Specifications

Browse online or download Specifications for Thermostats White Rodgers 1F97-71. White Rodgers 1F97-71 Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
PART NO. 37-5051A
9148
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
This wall-mounted, low voltage thermostat maintains
room temperature by controlling the operation of heating
and cooling systems. The user may program up to four
time/temperature settings per 24 hour period. The ther-
mostat stores independent heating and cooling programs
for each day of the week. The thermostat will store both
heating and cooling programs simultaneously. Three
"AA" Energizer
®
batteries will maintain the stored pro-
gram for approximately one year, if incoming power
should fail. If power failure is extensive and the program
is lost, after power restoration, the thermostat will auto-
matically maintain a factory preprogrammed heating tem-
perature of 64°F or a cooling temperature of 82°F.
INSTALLATION INSTRUCTIONS
1F97-71
7-Day Electronic Digital Thermostat
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5329
Printed in U.S.A.
PRECAUTIONS
If in doubt about whether your wiring is millivolt, line, or low
voltage, have it inspected by a qualified heating and air
conditioning contractor, electrician, or someone familiar
with basic electricity and wiring.
R
WHITE-RODGERS
Do not exceed the specification ratings.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
To prevent electrical shock and/or equipment
damage, disconnect electric power to system, at
main fuse or circuit breaker box, until installation
is complete.
Do not use on circuits exceeding specified volt-
age. Higher voltage will damage control and
could cause shock or fire hazard.
Do not short out terminals on gas valve or pri-
mary control to test. Short or incorrect wiring will
burn out thermostat and could cause personal
injury and/or property damage.
CAUTION
!
WARNING
!
Description ......................................................... 1
Precautions ........................................................ 1
Specifications ..................................................... 2
Installation.......................................................... 2
New Installation
Select Thermostat Location
Route Wires to Location
Replacement Installation
Remove Old Thermostat
Attach Subbase to Wall
Attach Thermostat to Subbase
Operation ........................................................... 6
System Configuration
A. Set Group A Option Switches
B. Set Group B Option Switches
C. Electric Heat Systems
Check Thermostat Operation
Fan Operation
Heating System
Cooling System
Troubleshooting
CONTENTS
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - WHITE-RODGERS

PART NO. 37-5051A9148Operator: Save these instructions for future use!FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLYBEFORE INSTALLING OR OPERA

Page 2 - INSTALLATION

2SPECIFICATIONSELECTRICAL DATAElectrical Rating:17 to 30v AC 50/60 Hz.0.05 to 1.5 Amps1.5 Amps Maximum Total Load (All terminals combined)Anticipa

Page 3 - REPLACEMENT INSTALLATION

3REPLACEMENT INSTALLATIONREMOVE OLD THERMOSTAT1. Shut off electricity at the main fuse box until installa-tion is complete. Verify power is off with

Page 4 - From 24vAC transformer

4All wiring diagrams are for typical systems only. Refer toequipment manufacturers' instructions for specific sys-tem wiring information.To prev

Page 5 - (through zone valve)

5RHYMVTHERMOSTATSYSTEMG WFigure 8. Typical Wiring Diagram for Millivolt Systems6MillivoltSystemRCGRC6MVYWRHThermostat Terminal ConnectionsFrom milliv

Page 6 - OPERATION

6ATTACH THERMOSTAT TO SUBBASEIT IS RECOMMENDED THAT YOU SET OPTIONSWITCHES TO DESIRED POSITION BEFORE ATTACH-ING ON SUBBASE (see OPERATION). IT IS A

Page 7 - CHECK THERMOSTAT OPERATION

7between heating and cooling programs to maintaindesired room temperature.2. Manual Changeover (Heating/Cooling SystemsOnly)3. Heat Only Systems4. Coo

Page 8 - TROUBLESHOOTING

erly, determine if automatic changeover is desired (seeSYSTEM CONFIGURATION).Refer to the OPERATION GUIDE if you need additionalinformation on thermos

Comments to this Manuals