PART NO. 37-6159G
Replaces 37-6159F
1023
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.
Operator: Save these instructions for future use!
The 36G/J22, 36G/J23, 36G/J24 and 36G/J52 combination
gas valves are designed for direct spark ignition (DSI) and
hot surface ignition (HSI) system applications. These valves
are equipped with redundant and main solenoid valves that
control gas fl ow to the main burners, a pressure regulator
and a two-position on/off switch for regulation and electrical
shut-off of the solenoid valves. The 36G/J23, 36G/J24 and
36G/J52 are also equipped with a slow-opening pressure
regulator for softer lighting characteristics.
DESCRIPTION
SPECIFICATIONS
Type of Gas: Natural gas
LP gas (use conversion kit)
Pressure Regulator Setting:
Nat. Gas – 2.5 to 5.0" W.C.
LP Gas 7.0 to 12.0"W.C.
Ambient Temperature: -40° to 175°F
Pressure Rating: 14" W.C. (1/2 PSI) max.
Voltage: 24 VAC
Frequency: 50/60 Hz
Current: .360 amps
Mounting Positions:
Multipoise – Control may be mounted in any position.
Parts and Accessories:
F92-0656 - LP to Natural Gas Conversion Kit for use
on Single Stage 36C, D, E, F, G, H, J valves. Regulation
range 2.5" to 5.0" W.C.
F92-0659 - Natural to Regulated LP Gas conversion
Kit for use on Single Stage 36C, D, E, F, G, H, J valves.
Regulation range 7.0" to 12.0" W.C.
F92-1003 - Adapter Kit for the 36G Gas Valves. Kit in-
cludes: Connector (5/16" to 1/4" hose barb), tube (5/16"
O.D.) and Hex Wrench (3/32").
36G22, 36G23, 36G24 & 36G52
36J22, 36J23, 36J24 & 36J52
DSI and HSI Single Stage Combination Gas Valve
INSTALLATION INSTRUCTIONS
CONTENTS
Description ........................................................ 1
Specifi cations .................................................... 1
Precautions ....................................................... 2
Installation ......................................................... 3
System Wiring
Adjustment ........................................................ 4
Pressure Regulator Adjustment
Lighting Instructions ........................................... 5
Notes ................................................................... 6
36G
36J
www.white-rodgers.com
www.emersonclimate.com
PIPE SIZES/CAPACITIES
Pipe Sizes
Available
(inches)
Capacity (BTU/hr) at
1” pressure drop across valve
1/2" x 1/2" NPT
any combination
140,000
AGA Std. Nat. Gas
(1,000 BTU/cu. ft.)
226,800
LP Gas
(2,500 BTU/cu. ft.)
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - INSTALLATION INSTRUCTIONS

PART NO. 37-6159GReplaces 37-6159F1023FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PE

Page 2 - THE FOLLOWING PRECAUTIONS

2WARNING!If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life.DO

Page 3 - INSTALLATION

3All piping must comply with local codes, ordinances, and/or national fuel gas codes.NOTESYSTEM WIRINGREFER TO AND FOLLOW THE APPLIANCE MANU-FACTURER’

Page 4 - ADJUSTMENT

4PRESSURE REGULATOR ADJUSTMENTControls are shipped from the factory with the regulator set as specifi ed on the control label. Consult the appli-ance r

Page 5 - LIGHTING INSTRUCTIONS

5TO TURN OFF GAS TO APPLIANCEOPERATING INSTRUCTIONSFOR YOUR SAFETY READ BEFORE OPERATINGWARNING!If you do not follow these instructions exactly, a fir

Page 6

6NOTES

Page 7

7NOTES

Page 8 - The Emerson logo is a