Integrated Furnace Control
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
INSTALLATION INSTRUCTIONS
The 50A65-5165 is an automatic gas interrupted
ignition control that employs a microprocessor to
continually monitor, analyze, and control the proper
operation of the gas burner, inducer, and fan.
Signals interpreted during continual surveillance of
the thermostat and flame sensing element initiate
automatic ignition of the burner, sensing of the flame,
and system shut-off during normal operation.
These controls incorporates system fault analysis for
quick gas flow shut-off, coupled with automatic ignition
retry upon sensing a fault correction. It is designed as a
replacement for the following controls:
PRECAUTIONS
Installation should be done by a qualified heating and
air conditioning contractor or licensed electrician.
If in doubt about whether your wiring is millivolt, line, or
low voltage, have it inspected by a qualified heating and
air conditioning contractor or licensed electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should
be handled carefully. Rough handling or distorting
components could cause the control to malfunction.
Following installation or replacement, follow
manufacturer’s recommended installation/service
instructions to ensure proper operation.
www.white-rodgers.com
www.emersonclimate.com
PART NO. 37-7516A
1409
CAUTION
!
Do not short out terminals on gas valve or primary
control. Short or incorrect wiring may damage
the thermostat.
WARNING
!
Failure to comply with the following warnings could
result in personal injury or property damage.
FIRE HAZARD
• Donotexceedthespeciedvoltage.
• Replaceexistingcontrolwithexactmodeland
dash number.
• Protectthecontrolfromdirectcontactwithwater
(dripping, spraying, rain, etc.).
• If the controlhasbeenindirectcontactwith
water, replace the control.
• Label all wires before disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation.
• Routeandsecurewiringawayfromame.
SHOCK HAZARD
• Disconnectelectricpowerbeforeservicing.
• Ensureproperearthgroundingofappliance.
• Ensureproperconnection oflineneutraland
line hot wires.
EXPLOSION HAZARD
• Shutoffmaingastoapplianceuntilinstallation
is complete.
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - 50A65-5165

Trane White-RodgersCNT05164 50A65-475CNT05165 50A65-47650A65-516550A65-5165Integrated Furnace ControlFAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREF

Page 2 - INSTALLATION

2SPECIFICATIONS INSTALLATION ELECTRICAL RATINGS [@ 77°F (25°C)]: Input Voltage: 25 VAC 50/60 Hz Max.InputCurrent@25VAC:0.45 amp Relay Load

Page 3 - WIRING

3 WIRINGCTWIN*TWIN*RGWYEAC NHUM NXFMR NLINE NCIR NIGN NIND NIGNINDHUMEACXFMRLINEPARKPARKHEATCOOLIGNITORYWGRTHERMOSTAT50A65-475or 50A65-476in otherfu

Page 4

4WIRING 50A65-5165TERMINALTERMINALTYPESYSTEM COMPONENTCONNECTIONTYPICAL SYSTEM WIRING TABLE low voltage thermostat W terminal (or equivalent)

Page 5 - HEAT MODE

5 OPERATION OPTION SWITCHESThe option switches on the 50A65-5165 control are used to determine the length of the heat delay-to-fan-off periods and c

Page 6 - DIAGNOSTIC FEATURES

6SYSTEM LOCKOUT AND DIAGNOSTIC FEATURESSYSTEM LOCKOUT FEATURESWhen system lockout occurs, the gas valve is de-energized, the circulator blower is ener

Page 7

7Auto Restart – After one (1) hour of internal or external lockout, the control will automatically reset itself and go into an auto restart purge for