Installation Instructions for
Heating & Air Conditioning
1F79
Non- Programmable
Heat Pump Thermostat
CONTENTS
Preparations .................................................. 1
Thermostat Details ........................................ 1
Removing Old Thermostat .........................1-2
Mounting and Wiring ..................................2-3
Check Thermostat Operation ..................... 4-5
Specifications ................................................ 5
Troubleshooting ......................................... 5-6
PREPARATIONS
THERMOSTAT DETAILS
REMOVING OLD THERMOSTAT
Before removing wires from old thermostat’s switching subbase,
label each wire with the terminal designation it was removed from.
1. Remove Old Thermostat: A standard heat/cool thermostat
consists of three basic parts:
a. The cover, which may be either a snap-on or hinge type.
b. The base, which is removed by loosening all captive screws.
c. The switching subbase, which is removed by unscrewing
the mounting screws that hold it on the wall or adaptor plate.
2. Shut off electricity at the main fuse box until installation is
complete. Ensure that electrical power is disconnected.
3. Remove the front cover of the old thermostat. With wires still
attached, remove wall plate from the wall. If the old thermostat
has a wall mounting plate, remove the thermostat and the wall
mounting plate as an assembly.
4. Identify each wire attached to the old thermostat using the
labels enclosed with the new thermostat.
5. Disconnect the wires from the old thermostat one at a time. DO
NOT LET WIRES FALL BACK INTO THE WALL.
6. Install new thermostat using the following procedures.
To prevent electrical shock and/or equipment damage,
disconnect electrical power to the system at the main
fuse or circuit breaker until installation is complete.
CAUTION
!
Printed in U.S.A.
PART NO. 37-6499A
0342
WHITE-RODGERS
EMERSON ELECTRIC CO.
ST. LOUIS, MISSOURI
www.white-rodgers.com
Failure to follow and read all instructions carefully
before installing or operating this control could cause
personal injury and/or property damage.
Assemble tools required as shown below.
YOUR THERMOSTAT REPLACES
1
2
3
WIRE CUTTER/STRIPPER
HAND OR POWER
DRILL WITH 3/16 INCH
DRILL BIT, IF NEEDED
FLAT BLADE SCREWDRIVER
SPIRIT LEVEL OR PLUMB BOB AND LINE OPTIONAL—
THERMOSTAT DOES NOT NEED TO BE LEVEL TO WORK PROPERLY
Figure 1. Thermostat base
W905
Clip for
Slow Cycle
W904
Clip for
Celsius
Mounting
hole
W906 for Emergency
Heat Second Stage
Fan Control
O/B
Terminal
Switches
Selection
Mounting
hole
Description
Heat Pump (No Aux or Emergency Heat) Yes
Heat Pump (with Aux or Emergency Heat) Yes
Standard Heat & Cooling Systems No
Standard Heat Only Systems No
Millivolt Heat Only Systems – Floor or Wall Furnaces No
Standard Central Air Conditioning No
Gas or Oil Heat No
Electric Furnace No
Hydronic (Hot Water) Zone Heat – 2 Wires No
Hydronic (Hot Water) Zone Heat – 3 Wires No
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - YOUR THERMOSTAT REPLACES

Installation Instructions forHeating & Air Conditioning1F79Non- ProgrammableHeat Pump ThermostatCONTENTSPreparations ...

Page 2 - MOUNTING AND WIRING

www.white-rodgers.comMOUNTING AND WIRINGTake care when securing and routing wires so they donot short to adjacent terminals or rear of thermostat.Pers

Page 3 - CONTINUED FROM SECOND PAGE

www.white-rodgers.comMOUNTING AND WIRINGCONTINUED FROM SECOND PAGE4LRE24 VAC120 VACHotSYSTEMMONITORSWITCHNeutralTHERMOSTATSYSTEMG W2Figure 2. Typical

Page 4 - CHECK THERMOSTAT OPERATION

CAUTION!CHECK THERMOSTAT OPERATIONwww.white-rodgers.comNOTETo prevent static discharge problems, touch side of ther-mostat to release static build-up

Page 5 - Configuration Menu

www.white-rodgers.comCHECK THERMOSTAT OPERATIONCONTINUED FROM FOURTH PAGE51Step Press Button(s) Displayed Press or(Factory Default) to select

Page 6 - TROUBLESHOOTING

Symptom Possible Cause Corrective ActionNo Heat 1. Pilot light not lit. Re-light pilot.2. System Switch not set to HEAT. Set System Switch to HEAT and