White Rodgers 1F90W-71 Specifications Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
6
ATTACH THERMOSTAT TO SUBBASE
IT IS RECOMMENDED THAT YOU SET OPTION
SWITCHES TO DESIRED POSITION BEFORE ATTACH-
ING ON SUBBASE (see OPERATION). IT IS ALSO
RECOMMENDED THAT YOU PROGRAM THE
THERMOSTAT WITH BATTERIES INSTALLED BE-
FORE ATTACHING ON SUBBASE (see OPERATION
GUIDE for programming instructions).
POWER TO THERMOSTAT MUST BE OFF BE-
FORE ATTACHING THERMOSTAT TO WALL.
FAILURE TO TURN OFF POWER BEFORE AT-
TACHING THERMOSTAT MAY CAUSE EQUIP-
MENT DAMAGE DUE TO RAPID COMPRESSOR
CYCLING.
To attach thermostat to subbase, line up the plastic snap
guides at the bottom of the thermostat and the three
connector pins on the thermostat with the connectors
near the bottom left section of the subbase (when viewed
from the front). Gently pivot the thermostat up until the six
pin connectors and the plastic snaps lock into place (see
Fig. 12). Be gentle when attaching thermostat. If the
thermostat does not seem to be attaching to the subbase
easily, make sure that the connector pins and plastic
snaps are properly aligned, and that excess wire is
pushed into the wall. Damage to the thermostat may
occur if force is used.
CAUTION
!
ENGAGE TWO LOWER GUIDES;
PIVOT UP
Figure 13. Attaching thermostat to subbase
SYSTEM CONFIGURATION
A. SET GROUP A OPTION SWITCHES
ANY TIME GROUP B OPTION SWITCHES ARE
CHANGED, THE "AA" BATTERIES MUST BE REMOVED
FOR A MINIMUM OF 2 MINUTES. DO NOT REMOVE
THE BATTERIES WHEN CHANGING GROUP A OP-
TION SWITCHES.
1. Total Keypad Activity
2. Total Keypad Lockout — All thermostat buttons are
disabled.
3. Limited Temperature Range — Temperature may
be raised or lowered within programmed temperature
limits (temperature adjustment cannot exceed the
lowest cooling or highest heating program tempera-
tures).
OPERATION
B. SET GROUP B OPTION SWITCHES
ANY TIME GROUP B OPTION SWITCHES ARE
CHANGED, THE "AA" BATTERIES MUST BE REMOVED
FOR A MINIMUM OF 2 MINUTES. DO NOT REMOVE
THE BATTERIES WHEN CHANGING GROUP A OP-
TION SWITCHES.
1. Automatic Changeover (Heating/Cooling Systems
Only) — enables thermostat to automatically switch
between heating and cooling programs to maintain
desired room temperature.
NOTE
ON
12
Switch #1 OFF
Switch #2 OFF
ON
12
Switch #1 ON
Switch #2 OFF
ON
12
Switch #1 OFF
Switch #2 ON
Figure 13. Back of Thermostat
Option Switches
3-pin Connector
6-pin Connector
Batteries
W14 W22
(Group A)
(Group B)
NOTE
ON
123
Switch #1 ON
Switch #2 OFF
Switch #3 (see step B5)
Page view 5
1 2 3 4 5 6 7 8

Comments to this Manuals

No comments