Symptom Possible Cause Corrective Action
No Heat/No Cool/No Fan 1. Blown fuse or tripped circuit breaker. Replace fuse or reset breaker.
(common problems) 2. Furnace power switch to OFF. Turn switch to ON.
3. Furnace blower compartment door or Replace door panel in proper position to engage
panel loose or not properly installed. safety interlock or door switch.
No Heat 1. Pilot light not lit. Re-light pilot.
2. SYSTEM Switch not set to HEAT. Set SYSTEM Switch to HEAT and raise setpoint
temperature above room temperature.
3. Loose connection to thermostat or system. Verify thermostat and system wires are securely
attached.
4. Furnace Lock-Out Condition. Heat may also Many furnaces have safety devices that shut
be intermittent. down when a lock-out condition occurs. If the
heat works intermittently contact the furnace
manufacturer or local service person for
assistance.
5. Heating system requires service or Diagnostic: Set SYSTEM Switch to HEAT and
thermostat requires replacement. raise the setpoint above room temperature. Within
a few seconds the thermostat should make a soft
click sound. This sound usually indicates the
thermostat is operating properly. If the thermostat
does not click, try the reset operation listed below.
If the thermostat does not click after being reset
contact your heating and cooling service person
or place of purchase for a replacement. If the
thermostat clicks, contact the furnace manufac
turer or a service person to verify the heating is
operating correctly.
No Cool 1. SYSTEM Switch not set to Cool. Set SYSTEM Switch to COOL and lower setpoint
temperature below room temperature.
2. Loose connection to thermostat or system. Verify thermostat and system wires are securely
attached.
3. Cooling system requires service or Same procedure as diagnostic for No Heat
thermostat requires replacement. condition except set the thermostat to COOL and
lower the setpoint below the room temperature.
There may be up to a five minute delay before the
thermostat clicks in Cooling.
www.white-rodgers.com
6
ELECTRICAL DATA
Electrical Rating:
0 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
SPECIFICATIONS
7
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-40°F to 150°F
TROUBLESHOOTING
Reset Operation
If a voltage spike or static discharge blanks out the display or
causes erratic thermostat operation you can reset the thermo-
stat by pressing and at the same time while moving
the SYSTEM switch from OFF to HEAT. This also resets the
factory defaults. If the thermostat has power, has been reset
and still does not function correctly contact your heating/cooling
service person or place of purchase.
Batteries
For optimum performance, we recommend replacing batteries
once a year with fresh AAA Energizer
®
alkaline batteries.