White Rodgers 1F95-1280 Operations Instructions Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
PROGRAMMING
Energy Saving Factory Pre-Program
The 1F95-1280 thermostats are programmed with the energy saving settings shown in the table below for all days of the week.
If this program suits your needs, simply set the thermostat clock and press the RUN key.
The table below shows the factory set heating and cooling schedule for all days of the week.
Day Night
Heating Program
6:00 AM 70°F 10:00 PM 62°F
Cooling Program
6:00 AM 75°F 10:00 PM 78°F
Enter the Heating Program
1. Press the Menu key and then press Set Schedule. Press
SYSTEM key to select "Heat" in the system switch area
indicating the active mode being programmed. You can
switch to the other mode by pressing the system switch at
any time.
2. The top of the display will show the day(s) being pro-
grammed. The time and set at temperature are also
displayed. "Day" will also be displayed to indicate the
period.
3. Press
or key to change the temperature to your
selected temperature for the 1st heating period (Morning).
4. Press
or key to adjust the start time for period.
The time will change in 15 minute increments.
5. Press FAN to select Auto or Prog.
6. After you have set the time and the temperature for the
period to begin, press Set Schedule to advance to the
next program period.
7. Repeat steps 2 through 6 until all of the program times
and temperatures are set for all program periods on
that day.
8. Press "Advance Day" to change to the next day and
repeat steps 2 through 8.
9. When programming is complete and all of the times and
temperatures match your desired heating schedule,
press Run Schedule. The thermostat will now run your
program.
Enter the Cooling Program
1. Press the SYSTEM key until the "Cool" icon appears.
2. Follow Enter Heating Program instructions for entering
cooling times and temperatures.
Automatic Schedule
Auto Schedule Heat is a fast way to program all the heating
temperatures during the day to a comfortable temperature
and then lower the temperature 6° at night. Auto Schedule
Cool will program all of the cooling time periods to the same
temperature.
Note: Auto Schedule is available only when the thermostat
is first powered on, after the thermostat has been reset, or
anytime you turn AS on in the Configuration Menu (item 18
AS Heat or 19 AS Cool).
Heating Example:
1. In Heat mode, press Auto Schedule once.
2. Press
or to select a comfortable day time tempera-
ture (example 72°).
3. Press Auto Schedule again. Your thermostat is now pro-
grammed for 72° from 6:30 AM until 10:30 PM at 72°. At
10:30 PM, your thermostat will set back 6° to 66°.
Your heating program for each day of the week will look like
this:
6:30 72°
10:30 66°
Cooling Example:
1. In cool, press Auto Schedule once.
2. Press
or to select a comfortable cooling tempera-
ture (example 75°).
3. Press Auto Schedule again. Your thermostat is now pro-
grammed for 75° for all cooling time periods.
Your cooling program for each day of the week will look like
this:
6:30 75°
10:30 75°
Programmable Fan Option
In the Set Schedule (programming mode) pressing Fan will
alternate the fan setting between FAN Auto and FAN Prog.
FAN Auto runs the fan as needed with the heating or cooling.
FAN Prog programs the fan to run continuously for the heat-
ing or cooling time period you are programming.
Example: Press the SYSTEM key to select Heat.
Press the Menu key once to display Set Schedule.
Press Set Schedule once to display the 1st heating program
period. The time and temperature for this period will show on
the display. Press the FAN key until it displays FAN Prog. The
fan is now programmed to run continuously for this time pe-
riod. The fan can be programmed for any or all time and tem-
perature settings in heating and cooling. To cancel program
fan for a time period, enter the heating or cooling program
(Menu, Set Schedule) and advance to the time/temperature
period you want to cancel. Press the fan key and FAN Prog
will change to FAN Auto.
11
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16

Comments to this Manuals

No comments