Integrated Furnace Control
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
INSTALLATION INSTRUCTIONS
The 50A55-3797 is an automatic gas interrupted
ignition control that employs a microprocessor to
continually monitor, analyze, and control the proper
operation of the gas burner, inducer, and fan.
Signals interpreted during continual surveillance of
the thermostat and flame sensing element initiate
automatic ignition of the burner, sensing of the flame,
and system shut-off during normal operation.
These controls incorporate system fault analysis for
quick gas flow shut-off, coupled with automatic ignition
retry upon sensing a fault correction. It is designed as a
replacement for the following controls:
PRECAUTIONS
Installation should be done by a qualified heating and air
conditioning contractor or licensed electrician.
If in doubt about whether your wiring is millivolt, line, or
low voltage, have it inspected by a qualified heating and
air conditioning contractor or licensed electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
Following installation or replacement, follow manufacturer’s
recommended installation/service instructions to ensure
proper operation.
WARNING
Failure to comply with the following warnings could
result in personal injury or property damage.
FIRE HAZARD
• Donotexceedthespeciedvoltage.
• Replaceexistingcontrolwithexactmodeland
dash number.
• Protectthecontrolfromdirectcontactwithwater
(dripping, spraying, rain, etc.).
• If the controlhasbeenindirectcontactwith
water, replace the control.
• Label all wires before disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation.
• Routeandsecurewiringawayfromame.
SHOCK HAZARD
• Disconnectelectricpowerbeforeservicing.
• Ensureproperearthgroundingofappliance.
• Ensureproperconnection oflineneutraland
line hot wires.
EXPLOSION HAZARD
• Shutoffmaingastoapplianceuntilinstallation
is complete.
www.white-rodgers.com
www.emersonclimate.com
PART NO. 37-7515B
Replaces 37-7515A
1422
CAUTION
Donotshortoutterminalsongasvalveorprimary
control. Short or incorrect wiring may damage
the thermostat.