Integrated Furnace Control
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
INSTALLATION INSTRUCTIONS
The 50A55-3797 is an automatic gas interrupted
ignition control that employs a microprocessor to
continually monitor, analyze, and control the proper
operation of the gas burner, inducer, and fan.
Signals interpreted during continual surveillance of
the thermostat and flame sensing element initiate
automatic ignition of the burner, sensing of the flame,
and system shut-off during normal operation.
These controls incorporate system fault analysis for
quick gas flow shut-off, coupled with automatic ignition
retry upon sensing a fault correction. It is designed as a
replacement for the following controls:
PRECAUTIONS
Installation should be done by a qualified heating and air
conditioning contractor or licensed electrician.
If in doubt about whether your wiring is millivolt, line, or
low voltage, have it inspected by a qualified heating and
air conditioning contractor or licensed electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
Following installation or replacement, follow manufacturer’s
recommended installation/service instructions to ensure
proper operation.
WARNING
!
Failure to comply with the following warnings could
result in personal injury or property damage.
FIRE HAZARD
• Donotexceedthespeciedvoltage.
• Replaceexistingcontrolwithexactmodeland
dash number.
• Protectthecontrolfromdirectcontactwithwater
(dripping, spraying, rain, etc.).
• If the controlhasbeenindirectcontactwith
water, replace the control.
• Label all wires before disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation.
• Routeandsecurewiringawayfromame.
SHOCK HAZARD
• Disconnectelectricpowerbeforeservicing.
• Ensureproperearthgroundingofappliance.
• Ensureproperconnection oflineneutraland
line hot wires.
EXPLOSION HAZARD
• Shutoffmaingastoapplianceuntilinstallation
is complete.
www.white-rodgers.com
www.emersonclimate.com
PART NO. 37-7515B
Replaces 37-7515A
1422
CAUTION
!
Donotshortoutterminalsongasvalveorprimary
control. Short or incorrect wiring may damage
the thermostat.
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - 50A55-3797

Trane White-RodgersCNT02891 50A55-474CNT03799 50A55-476CNT02789 50A55-57150A55-379750A55-3797Integrated Furnace ControlFAILURE TO READ AND FOLLOW ALL

Page 2 - INSTALLATION

2SPECIFICATIONS INSTALLATION ELECTRICAL RATINGS [@ 77°F (25°C)]: Input Voltage: 25 VAC 50/60 Hz Max.InputCurrent@25VAC:0.45 amp Relay Load

Page 3 - WIRING

3 WIRINGCRGWYYWGRTHERMOSTATCOMPRESSORCONTACTORELECTRONICAIR CLEANERCIRCULATORBLOWER50A55-379724 VAC120 VAC24 VAC CLASS IITRANSFORMERHOT(LINE)NEUTRAL

Page 4

4WIRING 50A55-3797TERMINALTERMINALTYPESYSTEM COMPONENTCONNECTIONTYPICAL SYSTEM WIRING TABLE low voltage thermostat W terminal (or equivalent)

Page 5 - MANUAL FAN ON MODE

5 OPERATION OPTION SWITCHESThe option switches on the 50A55-3797 control are used to determine the length of the heat delay-to-fan-off periods and c

Page 6 - OPERATION

62. Interrupt the 24 VAC power at the control for at least one second. You may also need to reset the flame rollout sensor switch.3. After one hour i

Page 7 - TROUBLESHOOTING

7Red LED Flash Error/Condition Comments/TroubleshootingSlow Flash Normal operation Normal – no Call for HeatFast Flash Normal operation Normal – Call

Page 8 - The Emerson logo is a

TECHNICAL SUPPORT: 1-888-725-9797White-Rodgers is a business of Emerson Electric Co.The Emerson logo is a trademark and service mark of Emerson Elec