WARNING
!
       


ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this product
may replace a product that contains mercury.
Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any spilled
mercury and place in a sealed container. For proper disposal of
a product containing mercury or a sealed container of spilled
mercury, place it in a suitable shipping container. Refer to
 for location to send product
containing mercury.
CAUTION
!
      


APPLICATIONS
INDEX
 Applications


Single Stage Gas, Oil, Electric, Heat Only, Cool Only or Heat Cool Systems
1/1
Multi-Stage Gas, Oil, Electric, Heat Only, Cool Only or Heat Cool Systems
2/2
Heat Pump Single or Two Compressor Systems with up to 2 Stages of Aux / Em Heat
4/2
Heat Pump with Dual Fuel Single or Two Compressor Systems with up to 2 Stages of Fossil fuel Heat
4/2
SPECIFICATIONS
Electrical Rating:
Input-Hardwire ....................................................... 20 to 30 VAC
Terminal Load ................................................................ 1.0A per terminal, 2.5A maximum all terminals combined
Setpoint Range .............................................................. 45° to 99°F (7° to 37°C)
Operating Ambient ........................................................ 32°F to +105°F (0° to +41°C)
Operating Humidity ....................................................... 90% non-condensing max.
Shipping Temperature Range ......................................... -40° to +150°F (-40° to +65°C)
Dimensions Interface ..................................................... 4-1/2”H x 6”W x 1-1/4”D
Dimensions Control ....................................................... 5-1/2”H x 5-3/4”W x 1-1/2”D

Mount Return Air Sensor and Equipment Control
3
Equipment Control Module Wiring to HVAC Equipment
4
Install Batteries
5
Installer Quick Reference
5

6
Check System Operation
7
Locate and Mount Comfort Interface
8
View Wireless Devices
8
Troubleshooting
10
Page view 1
1 2 3 4 5 6 7 ... 11 12

Comments to this Manuals

No comments